Passive air sampling of flame retardants and plasticizers in Canadian homes using PDMS, XAD-coated PDMS and PUF
Joseph O Okeme1, Congqiao Yang2, Atousa Abdollahi3
1Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON, M1C 1A4, Canada.
Abstract:
Passive air samplers (PAS) were evaluated for measuring indoor concentrations of phthalates, novel brominated flame retardants (N-BFRs), polybrominated diphenyl ethers (PBDEs), and organophosphate esters (OPEs). Sampling rates were obtained from a 50-day calibration study for two newly introduced PAS, polydimethylsiloxane (PDMS) or silicone rubber PAS (one with and one without a coating of styrene divinyl benzene co-polymer, XAD) and the commonly used polyurethane foam (PUF) PAS. Average sampling rates normalized to PAS surface area were 1.5 ± 1.1 m3 day-1 dm-2 for both unsheltered PDMS and XAD-PDMS, and 0.90 m3 ± 0.6 day-1dm-2 for partially sheltered PUF. These values were derived based on the compound-specific sampling rates measured here and in the literature for the PAS tested, to reasonably account for site-specific variability of sampling rates. PDMS and PUF were co-deployed for three weeks in 51 homes located in Ottawa and Toronto, Canada. Duplicate PUF and PDMS samplers gave concentrations within 10% of each other. PDMS and PUF-derived air concentrations were not statistically different for gas-phase compounds. PUF had a higher detection of particle-phase compounds such as some OPEs. Phthalate and OPE air concentrations were ∼100 times higher than those of N-BFRs and PBDEs. Concentrations were not systematically related to PM10, temperature or relative humidity. We conclude that both PAS provide replicable estimates of indoor concentrations of these targeted semi-volatile organic compounds (SVOCs) over a three-week deployment period. However, PUF is advantageous for collecting a wider range of compounds including those in the particle phase.
Related Concept Videos
Retarders
The function of retarders is to delay the setting of concrete, and this effect can be measured using a penetration test. The retardation process involves adding...
Plasticity
Plasticizers
Plasticizers function by using surface-active agents to create repulsive electrostatic forces between cement particles. This dispersion enhances the concrete's...
Flame Photometry: Overview
Flame Photometry: Lab
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...