Assessment of five different probes for lung ultrasound in critically ill patients: A pilot study
Xavier Bobbia1, Margaux Chabannon2, Thierry Chevallier3
1Department of Anesthesiology, Emergency and Critical Care Medicine, Intensive Care Unit, Nîmes University Hospital, place du Pr Debré, 30029 Nîmes, France; Emergency Department, Timone 2 Hospital, Aix-Marseille University, Marseille, France.
Introduction:
The present study was aimed at comparing the diagnosis concordance of five echo probes of lung ultrasound (LUS) with CT scans in intensive care and emergency patients with acute respiratory failure.
Materials:
This prospective, observational, pilot study involved 10 acute patients in whom a thoracic CT scan was performed. An expert performed an LUS reference exam using five different probes: three probes with a high-quality conventional echo machine (cardiac phased-array probe, abdominal convex probe, linear probe) and two probes (cardiac and linear) with a pocket ultrasound device (PUD). Then, a trained physician and a resident performed 'blinded' analyses by viewing the video results on a computer. The primary objective was to test concordance between the blinded echo diagnosis and the CT scan.
Results:
In the 100 LUS performed, the phased-array probe of the conventional machine and linear array probe of the PUD have the best concordance with the CT scan (Kappa coefficient=0.75 [CI 95%=0.54-0.96] and 0.62 [CI 95%=0.37-0.86], respectively) only for experts and trained physicians. The agreement was always poor for residents. Convex (abdominal) and linear transducers of conventional machines and the phased-array transducers (cardiac) of PUD have poor or very poor agreement, regardless of the physician's experience.
Conclusion:
Among the probes tested for LUS in acute patients, the cardiac probe of conventional machines and the linear probes of PUDs provide good diagnosis concordance with CT scans when performed by an expert and trained physician, but not by residents.
Related Concept Videos
Pilot and Numeric Relaying
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values
Lung Capacity
Critical Thinking
Colleges and universities are...