Related Experiment Video
Updated: Feb 11, 2026

Mouse In Vivo Placental Targeted CRISPR Manipulation
Published on: April 14, 2023
T2-weighted balanced steady-state free procession MRI evaluated for diagnosing placental adhesion disorder in late
Ang Yang1, Xue Hong Xiao2, Zhi Long Wang2
1MR department of Affiliated Zhongshan City Hospital of Sun Yat-sen University, Sun Wendong Road No. 2, Zhongshan City, Guangdong Province, China. yang19781230@gmail.com.
Objective:
This study evaluated the imaging characteristics and accuracy of T2-weighted (T2W) balanced steady-state free procession (b-SSFP) magnetic resonance imaging, relative to b-SSFP or single-shot fast spin echo (SSFSE), for the diagnosis of placental adhesion disorder (PAD).
Methods:
Fifty-one pregnant patients suspected of PAD were examined with T2W b-SSFP, b-SSFP and SSFSE. The image types were independently analysed for signs of PAD: abnormal placental bulge (APB), dark intraplacental bands (DIB), placental heterogeneity (PH) and placental protrusion into adjacent structures (PPAS). The sequences were compared for muscle-to-placenta signal ratio, signs of PAD and area under the receiver operating characteristic curve (AUC) for diagnostic accuracy of PAD.
Results:
PAD was confirmed in 34 women. The muscle-to-placenta signal ratio was highest in the T2W b-SSFP. The diagnostic rates of APB in T2W b-SSFP were comparable to that of b-SSFP, but were significantly higher than that of SSFSE. The rates of PH in SSFE were comparable to that of b-SSFP, but both were significantly lower than that of T2W b-SSFP. The rates of DIB were significantly higher in T2W b-SSFP images compared with SSFSE. Rates of PPAS were comparable among three sequences. The AUCs of the T2W b-SSFP, b-SSFP and SSFSE were 0.966, 0.890 and 0.823, respectively.
Conclusion:
T2W b-SSFP has high diagnostic accuracy for PAD relative to SSFSE or b-SSFP, which may be due to its high SNR, T2-weighting and lack of blur.
Key Points:
• Signal myometrium-to-placenta ratio was highest in the T2W b-SSFP images. • Diagnostic rate of APB in T2W b-SSFP was highest. • Diagnostic rate of DIB was higher in T2W b-SSFP than in SSFSE. • Diagnostic rate of PH in T2W b-SSFP was highest. • Maximum AUC for diagnostic accuracy of PAD was in T2W b-SSFP.
Insights
T2-weighted (T2W) balanced steady-state free procession (b-SSFP) MRI shows superior accuracy for diagnosing placental adhesion disorder (PAD) compared to other sequences. This advanced imaging technique offers higher signal-to-noise ratio and reduced blur for improved diagnostic capabilities.
Area of Science:
- Radiology
- Obstetrics & Gynecology
- Medical Imaging
Background:
- Placental adhesion disorder (PAD) poses significant risks during pregnancy.
- Accurate diagnosis of PAD is crucial for effective management.
- Conventional MRI sequences may have limitations in visualizing PAD characteristics.
Purpose of the Study:
- To evaluate the diagnostic accuracy of T2-weighted (T2W) balanced steady-state free procession (b-SSFP) MRI for PAD.
- To compare T2W b-SSFP with standard b-SSFP and single-shot fast spin echo (SSFSE) sequences.
- To identify specific imaging features indicative of PAD across different MRI sequences.
Main Methods:
- Fifty-one pregnant patients with suspected PAD underwent MRI using T2W b-SSFP, b-SSFP, and SSFSE sequences.
- Images were analyzed for abnormal placental bulge (APB), dark intraplacental bands (DIB), placental heterogeneity (PH), and placental protrusion into adjacent structures (PPAS).
- Sequences were compared based on muscle-to-placenta signal ratio, PAD sign detection rates, and area under the receiver operating characteristic curve (AUC).
Main Results:
- T2W b-SSFP demonstrated the highest muscle-to-placenta signal ratio.
- Diagnostic rates for APB and PH were significantly higher with T2W b-SSFP compared to SSFSE.
- The AUC for T2W b-SSFP (0.966) was superior to b-SSFP (0.890) and SSFSE (0.823), indicating higher diagnostic accuracy for PAD.
Conclusions:
- T2W b-SSFP MRI offers high diagnostic accuracy for placental adhesion disorder.
- The superior performance is attributed to T2W b-SSFP's high signal-to-noise ratio, T2-weighting, and reduced motion artifact.
- T2W b-SSFP is a valuable tool for diagnosing PAD, outperforming conventional b-SSFP and SSFSE sequences.
Related Concept Videos
Disorder of Water Balance
Dehydration
Dehydration occurs when the body loses fluids (particularly water).
Causes:
The major causes of dehydration include excessive sweating, fever, vomiting, diarrhea, and diuresis.
Signs and Symptoms:
Symptoms primarily include intense...
Disorders of Acid-Base Balance
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...
Balancing Redox Equations
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Gonadal and Placental Hormones
In males, testosterone is the primary gonadal androgen. It plays a central role in the maturation of male reproductive organs — the penis and testes. Additionally, testosterone is instrumental in the development of secondary sexual characteristics — a deep voice as well as facial and pubic hair...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...

