Minimisation of Signal Intensity Differences in Distortion Correction Approaches of Brain Magnetic Resonance
Dong-Hoon Lee1, Do-Wan Lee2, David Henry1
1Faculty of Health Sciences and Brain & Mind Centre, The University of Sydney, Sydney, New South Wales, Australia.
Objectives:
To evaluate the effects of signal intensity differences between the b0 image and diffusion tensor imaging (DTI) in the image registration process.
Methods:
To correct signal intensity differences between the b0 image and DTI data, a simple image intensity compensation (SIMIC) method, which is a b0 image re-calculation process from DTI data, was applied before the image registration. The re-calculated b0 image (b0ext) from each diffusion direction was registered to the b0 image acquired through the MR scanning (b0nd) with two types of cost functions and their transformation matrices were acquired. These transformation matrices were then used to register the DTI data. For quantifications, the dice similarity coefficient (DSC) values, diffusion scalar matrix, and quantified fibre numbers and lengths were calculated.
Results:
The combined SIMIC method with two cost functions showed the highest DSC value (0.802 ± 0.007). Regarding diffusion scalar values and numbers and lengths of fibres from the corpus callosum, superior longitudinal fasciculus, and cortico-spinal tract, only using normalised cross correlation (NCC) showed a specific tendency toward lower values in the brain regions.
Conclusion:
Image-based distortion correction with SIMIC for DTI data would help in image analysis by accounting for signal intensity differences as one additional option for DTI analysis.
Key Points:
• We evaluated the effects of signal intensity differences at DTI registration. • The non-diffusion-weighted image re-calculation process from DTI data was applied. • SIMIC can minimise the signal intensity differences at DTI registration.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Atomic Nuclei: Magnetic Resonance
Inertia Tensor
The diagonal components of the inertia tensor matrix represent the moments of inertia concerning the principal axes of the object. These primary axes are defined as the axes where the object experiences the least...
Diffusion