Monte Carlo method for gamma spectrometry based on GEANT4 toolkit: Efficiency calibration of BE6530 detector
Guembou Shouop Cebastien Joel1, Ndontchueng Moyo Maurice2, Nguelem Mekongtso Eric Jilbert3
1Atomic and Nuclear Spectroscopy, Archeometry, University of Liège, Bat. B15 Sart Tilman, 4000, Liege 1, Belgium; Fundamental Physics Laboratory, Mathematics, Applied Computer Sciences and Fundamental Physics, University of Douala, P.O.Box 24157 Douala, Cameroon; National Radiation Protection Agency, P.O. Box 33732, Yaounde, Cameroon.
Abstract:
The combination of gamma-ray spectrometry, the development of related Monte Carlo method and the GEANT4 (GEometry ANd Tracking) toolkit have been developed for gamma spectrometry simulation. The main objective was to validate simulation models of broad energy germanium (BEGe) detector geometry built in our laboratory (BE6530 model). Monte Carlo simulation of the geometry of BE6530 detector for efficiency calibration was carried out with GEANT4 toolkit. The simulated efficiencies curves using MC were compared with experimental results. Measurement uncertainties for both simulation and experimental estimations of the efficiency were assessed in order to see whether the consequences of the realistic measurement fall inside adequate cut-off points. The validation of the simulation was carried out by experimentally estimating the activity concentration in a reference sample and the comparison showed good correlation between experimental and simulation. Therefore, from the outcomes of this study, it can be concluded that Monte-Carlo simulation is a helpful, reasonable option that additionally gives more prominent adaptability, greater flexibility, precision and accuracy, and gained time when determining the detector response and efficiency in routine of environmental radioactivity monitoring.
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Calibration Curves: Correlation Coefficient