Aptamer-based microcantilever-array biosensor for profenofos detection
Chao Li1, Guangping Zhang1, Shangquan Wu1
1CAS Key Laboratory of Mechanical Behavior and Design of Material, Department of Modern Mechanics, University of Science and Technology of China, Hefei, 230027, China.
Abstract:
Profenofos, a highly poisonous organophosphorus pesticide, has been widely used in agricultural production. These pesticide residues have seriously influenced food security and threatened human health, and new methods with high sensitivity are greatly needed to detect profenofos. Here, we developed an aptamer-based microcantilever-array sensor operated in stress mode to detect profenofos, with advantages of being a label-free, highly sensitive, one-step immobilization method capable of quantitative and real-time detection. The microcantilevers were functionalized with a profenofos-specific aptamer (SS2-55), and then the specific binding of profenofos to aptamer induced a deflection of the microcantilever, which was monitored using an optical method in a real-time manner. The microcantilever deflection showed a positive relationship with profenofos concentration, and the detection limit was low to 1.3 ng mL-1 (3.5 nM) for profenofos, which was much lower than other aptamer-based detection methods. The selectivity of the sensor was verified with another organophosphorus pesticide. Additionally, we successfully detected profenofos dissolved in vegetable-soak solution. Our results showed that this aptamer-based microcantilever-array sensor is a convenient and label-free method for detecting profenofos in small amounts and has great potential for food-security applications.
Related Concept Videos
Base Excision Repair
The first step of...
Detection of Gross Error: The Q Test
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
Weak Base Solutions
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation:
DNA Base Pairing