In vitro study of a modified sagittal split osteotomy fixation technique of the mandible: a mechanical test
C L Sonego1, M A R Scheffer1, O L Chagas Júnior2
1Graduate Program in Dentistry, Oral and Maxillofacial Surgery, Lutheran University of Brazil, Canoas, RS, Brazil.
Abstract:
This study was performed to evaluate the compressive mechanical strength of rigid internal fixation (RIF) using 1.5-mm L-shaped plates fixed with monocortical screws in sagittal split osteotomy (SSO). Thirty synthetic hemimandibles, which had all undergone a 5-mm advancement, were divided into three groups: three 12-mm bicortical titanium screws were placed in an inverted L pattern in group A; one straight 2.0-mm system spaced titanium plate fixed with four 5-mm monocortical screws was used in group B; two 1.5-mm system L-shaped titanium plates, each fixed with four 5-mm monocortical screws, were used in group C. The models were subjected to compressive and progressive mechanical tests with forces applied in the area between the second premolar and first molar to verify resistance in Newtons (N). A displacement speed of 1mm/min was applied, with a maximum 10mm displacement of the distal segment or until disruption of the fixation. The deformity and/or eventual rupture of the plates were evaluated, and consequently their technical stability was determined. The results showed that the modified fixation technique tested in this study on synthetic mandibles resulted in adequate stability and superior mechanical behaviour compared to simulated osteosynthesis with the use of a straight 2.0-mm titanium plate.
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Carbon-dioxide Fixation
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
¹H NMR Signal Multiplicity: Splitting Patterns
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations