Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
Uday Yanamandra1, Amul Gupta2, Srinivasa A Bhattachar3
1Department of Hematology, Army Hospital (Research & Referral), New Delhi, India.
Context:
Optic nerve sheath diameter (ONSD) has long been accepted as a reliable proxy of intracranial pressure especially in critical care and bedside settings. The present consensus is to measure ONSD in both eyes and take average value, which is cumbersome and a potential cause of discomfort to the patient.
Aim:
We aim to compare the values of ONSD of the right and left eye in a random sample as measured by bedside ocular ultrasonography (USG) in Indian adults.
Settings And Design:
This was a prospective study conducted from September 2012 to March 2013 in the Department of Internal Medicine of a tertiary care hospital situated at moderate high altitude (11,500 ft) in India.
Materials And Methods:
Patients admitted with high altitude pulmonary edema (HAPE) were recruited by convenience sampling. The ONSD of both eyes were measured 3 mm behind the globe using a 7.5 MHz linear probe on the closed eyelids of supine subjects.
Statistical Analysis:
Analysis was done using SPSS 17.0.
Results:
A total of 47 patients of HAPE were recruited to the study with daily ONSD recording of both eyes during the admission period. The mean ONSD of the left eye was 4.60 (standard deviation [SD] = 0.71) whereas the mean ONSD of right eye 4.59 (SD = 0.72). The ONSD of the right eye and left eye was strongly correlated (correlation coefficient = 0.98 with P < 0.0001). The mean difference in the ONSD of both eyes (right-left) was -0.0044 (SD = 0.11) which was not statistically significant (P = 0.533).
Conclusion:
Our results suggest that the difference in ONSD of both eyes is not statistically significant in disease or health. This study also suggests that the ONSD of either eye can be predicted by the other eye recordings. Based on these findings, it can be suggested that during ocular USG for routine bedside/research purposes it is sufficient to measure ONSD of any of the one eye to save time and avoid discomfort to the patient.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc