Related Experiment Video
Updated: Feb 11, 2026

Technical Detail for Robot Assisted Pancreaticoduodenectomy
Published on: September 28, 2019
Internal Hernia Following Robotic Assisted Pancreaticoduodenectomy
Kai Qin1, Zhichong Wu2, Jiabin Jin2
1Pancreatic Disease Center, Department of General Surgery, Rui Jin Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China (mainland).
Abstract:
BACKGROUND Robotic assisted pancreaticoduodenectomy (RPD) is reported to be safe and feasible. Internal hernia (IH) after RPD is a serious but rarely reported complication. MATERIAL AND METHODS We retrospectively reviewed data of 231 patients who underwent RPD from October 2010 to December 2016. The incidence, symptoms, time of presentation, and outcome were investigated. RESULTS Five patients (2.6%) were diagnosed with IH. Significant correlation (P<0.001) between IH and transverse mesocolon defect was confirmed. In patients without defect closure, the incidence of IH was 62.5%, while patients who received defect closure experienced no IH. The median time between initial surgery and occurrence of IH was 76 days. The main symptoms were abdominal pain, nausea, and vomiting. All patients received abdominal computed tomography (CT) and were suspected to have IH according to imaging and symptoms. All patients underwent reoperation (2 laparoscopic and 3 open surgery). The median length of hospital stay was 13 days. No patient experienced a relapse after treatment. CONCLUSIONS Abdominal pain, nausea, and vomiting were common symptoms in our study patients who underwent RPD. IH should be suspected if there is a positive finding on CT. Timely reoperation is necaAbdominal pain, nausea, and vomiting were common symptoms in our study patients who underwent RPD. IH should be suspected if there is a positive finding on CT. Timely reoperation is necessary because IH may cause intestinal ischemia. Meticulous closure of the mesenteric defect is vital to avoid IH.essary because IH may cause intestinal ischemia. Meticulous closure of the mesenteric defect is vital to avoid IH.
Related Concept Videos
Internal Energy
Internal Energy
Internal Receptors
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
Internal and External Forces
International Nursing Organizations I
ICN member organizations work to advance the field of nursing and healthcare via policies, partnerships, lobbying, professional...

