Inter/Intraobserver Reliability of T1 Pelvic Angle (TPA), a Novel Radiographic Measure for Global Sagittal Deformity
Stephen M Plachta1, Heidi Israel1, Jennifer Brechbuhler1
1Department of Orthopaedic Surgery, Saint Louis University School of Medicine, Saint Louis, MO.
The T1 pelvic angle (T1PA) is a reliable radiographic measure for spinal sagittal alignment in healthy adults. Its accuracy is consistent across different experience levels and pelvic positions.
Area of Science:
- Orthopedics
- Radiography
- Spinal Biomechanics
Background:
- Existing literature suggests T1PA offers superior reliability for global sagittal alignment compared to traditional methods.
- Prior research primarily focused on postoperative spinal deformity patients.
- This study is the first to evaluate T1PA reliability in healthy subjects without spinal deformity.
Purpose of the Study:
- To assess the intra- and interobserver reliability of the T1 pelvic angle (T1PA) in healthy adults.
- To examine the relationship between T1PA measurements and pelvic position.
- To establish T1PA as a dependable radiographic measure for spinal sagittal alignment.
Main Methods:
- Seven orthopedic surgeons of varying experience measured T1PA in 50 healthy volunteers.
- Radiographs were taken in three pelvic positions: resting, maximal anterior rotation, and maximal posterior rotation.
- Intraclass correlation coefficients were used to determine intra- and inter-rater agreement.
Main Results:
- A very high level of agreement was observed for T1PA measurements (ICC = 0.98).
- Excellent intrarater reliability (>0.85) was achieved by all examiners across all pelvic positions.
- Inter-rater reliability demonstrated consistent T1PA measurements within ±2° of a gold standard, with T1PA varying based on pelvic rotation.
Conclusions:
- The T1 pelvic angle (T1PA) is a reproducible and reliable measure of global sagittal alignment.
- T1PA reliability is independent of the evaluator's training level.
- The influence of pelvic rotation on T1PA must be considered for accurate clinical application and correction targets.