Assessing CT acquisition parameters with visual-search model observers
Zohreh Karbaschi1, Howard C Gifford1
1University of Houston, Department of Biomedical Engineering, Houston, Texas, United States.
Abstract:
A principal difference between the channelized Hotelling (CH) and visual-search (VS) model observers is how they respond to noise texture in images. We compared the two observers in lesion-detection studies to evaluate linear and angular sampling parameters for CT. Simulated lung images were generated from a single two-dimensional mathematical torso phantom containing circular lesions of fixed radius and relative contrast. Projection datasets were produced for two detector pixel sizes and from 15 to 128 projections at 15 and 65 M counts per set. Filtered backprojection reconstructions were obtained with dimensions of [Formula: see text] and [Formula: see text]. A localization receiver operating characteristic study was conducted with two human observers, three single-feature VS observers, and a feature-adaptive VS observer. The effects of the sampling parameters on performance were similar for all of these observers. The CH observer, applied in location-known studies with and without background variability, was not affected by the variations in angular sampling. The two-stage VS framework was an effective modification of the CH observer for assessing the effects of noise texture on human-observer performance in this study.
More Related Videos
03:38Unilateral Lung Volume Analysis Using Micro-CT for Enhanced Assessment of Pulmonary Fibrosis in Preclinical Models
Published on: June 20, 2025
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Related Concept Videos
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Naturalistic Observations
Wave Parameters
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Light Acquisition
Observational Learning