Related Experiment Video
Updated: Feb 11, 2026

Focused Assessment with Sonography for Trauma FAST Exam: Image Acquisition
Published on: September 22, 2023
TEG Lysis Shutdown Represents Coagulopathy in Bleeding Trauma Patients: Analysis of the PROPPR Cohort
Jessica C Cardenas1,2, Charles E Wade1,2, Bryan A Cotton1,2
1Division of Acute Care Surgery, Department of Surgery, The University of Texas Health Science Center and the McGovern School of Medicine, Houston, Texas.
Background:
Thrombelastography (TEG) fibrinolysis shutdown after trauma is associated with increased mortality due to hypercoagulability-associated organ failure. However, a lack of mechanistic data has precluded the development of novel interventions to treat shutdown.
Objectives:
To define the pathophysiology of TEG shutdown in severely injured, bleeding patients through secondary analysis of the PROPPR trial.
Methods:
Fibrinolysis was characterized in PROPPR subjects using admission TEG lysis at 30 min (LY30) or plasmin-antiplasmin (PAP) levels. LY30 categories were low (<0.9%), moderate (0.9-2.9%), or high (≥ 3%). PAP was classified as low (<1,500 μg/L), moderate (1,500-20,000 μg/L), or high (>20,000 μg/L). Demographics, outcomes, admission TEG values, platelet count and function, standard coagulation tests, and coagulation proteins were compared.
Results:
Five hundred forty-seven patients had TEG data and 549 patients had PAP data available. Low LY30 was associated with reduced platelet count and aggregation, poorer TEG clot formation, prolonged clotting times, and reduced fibrinogen and alpha2 antiplasmin. Compared to moderate PAP, low PAP subjects had similar platelet parameters, TEG values, fibrinogen, and alpha2 antiplasmin, but reduced tPA, and elevated PAI-1. D-Dimer values increased as PAP increased, however patients with low LY30 had elevated D-Dimer compared with moderate LY30 patients. Most low LY30 deaths were due to TBI (45%) and hemorrhage (42%) versus one of each cause (TBI, hemorrhage, MOF) in low PAP patients.
Conclusions:
Low TEG LY30 does not reflect shutdown of enzymatic fibrinolysis with hypercoagulability, but rather a coagulopathic state of moderate fibrinolysis with fibrinogen consumption and platelet dysfunction that is associated with poor outcomes.
Related Concept Videos
The Representativeness Heuristic
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Tissue Homogenization and Cell Lysis
Mechanical methods of tissue homogenization
These methods rely on applying external physical force to disrupt...
Patient-centered Care
Pedigree Analysis
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...

