Related Experiment Video
Updated: Feb 11, 2026

Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model
Published on: May 24, 2024
Split-Depressed Lateral Tibial Plateau Fractures: A Comparison of Augmented Percutaneous Screws Versus Augmented
Richard J Bowles1, Vivek Chadayammuri1, Todd Baldini1
1Department of Orthopaedic Surgery, University of Colorado School of Medicine, Aurora, CO.
Objectives:
To compare the strength of fixation of percutaneous screw versus plate/screw fixation in a paired cadaver model of OTA 41-B3 (Schatzker type II) split-depression fractures of the lateral tibial plateau.
Methods:
Six matched pairs of cadaveric knees were acquired. An OTA 41-B3 (Schatzker type II) split-depression fracture was created in all specimens using a standardized method. One specimen from each matched pair of knees was fixed with percutaneous screws, and the other was fixed with a plate/screw construct. All specimens underwent augmentation of the central metaphyseal defect with calcium phosphate. Mean residual displacement (depression) was measured on thin-slice high-resolution computed tomography using a standardized methodology following 3 experimental conditions: (1) after they were fixed, before loading; (2) unloaded cycling (simulating postoperative range of motion exercises); and (3) loaded cycling (simulating postoperative weight-bearing). Load to failure was also compared.
Results:
After adjustment for baseline measurements, there was no significant difference in mean residual depression of the lateral tibial plateau between treatments groups after unloaded or loaded cyclic testing. Mean residual depression was less than 1 mm in both the treatment groups. Load to failure was statistically equivalent between treatment groups.
Conclusions:
In our cadaveric study, in combination with calcium phosphate augmentation for both methods, percutaneous screw fixation conferred comparable strength of fixation compared with plate/screw constructs for treatment of OTA 41-B3 (Schatzker type II) tibial plateau fractures.
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Long-term Depression
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...

