Related Experiment Video
Updated: Feb 11, 2026

Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
Published on: March 17, 2023
Development of microfluidic impedance cytometry enabling the quantification of specific membrane capacitance and
Yang Zhao1, Ke Wang2, Deyong Chen2
1R&D Center of Healthcare Electronics, Institute of Microelectronics, Chinese Academy of Sciences, Beijing, PR China.
Abstract:
This paper presents a new microfluidic impedance cytometry with crossing constriction microchannels, enabling the characterization of cellular electrical markers (e.g., specific membrane capacitance (Csm) and cytoplasm conductivity (σcy)) in large cell populations (~ 100,000 cells) at a rate greater than 100 cells/s. Single cells were aspirated continuously through the major constriction channel with a proper sealing of the side constriction channel. An equivalent circuit model was developed and the measured impedance values were translated to Csm and σcy. Neural network was used to classify different cell populations where classification success rates were calculated. To evaluate the developed technique, different tumour cell lines, and the effects of epithelial-mesenchymal transitions on tumour cells were examined. Significant differences in both Csm and σcy were found for H1299 and HeLa cell lines with a classification success rate of 90.9% in combination of the two parameters. Meanwhile, tumour cells A549 showed significant decreases in both Csm and σcy after epithelial-mesenchymal transitions with a classification success rate of 76.5%. As a high-throughput microfluidic impedance cytometry, this technique can add a new marker-free dimension to flow cytometry in single-cell analysis.
Related Concept Videos
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Cytoplasm
Protein Folding and Misfolding
The cytoplasm is the location for several cellular processes, including protein synthesis and folding. The aqueous nature of the cytosol promotes protein folding such that the hydrophobic amino acid side chains are buried in the protein...
Cytoplasm
Protein Folding and Misfolding
The cytoplasm is the location for several cellular processes, including protein synthesis and folding. The aqueous nature of the cytosol promotes protein folding such that the hydrophobic amino acid side chains are buried in the protein...
Equivalent Capacitance
Equivalent Capacitance
The following strategies are adopted to calculate...
Cell Specific Gene Expression