Validity of motion analysis using the Kinect system to evaluate single leg stance in patients with hip disorders
Makoto Asaeda1, Wataru Kuwahara2, Naoto Fujita2
1Division of Rehabilitation, Department of Clinical Practice and Support, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan; Sports Medical Center, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan.
Background:
Abnormal movements during single leg stance in patients with hip disorders could be detected by the Kinect system as well as the three-dimensional motion analysis system. However, validity of the Kinect system to evaluate single leg stance in patients with hip disorders remains unknown.
Research Question:
To investigate the concurrent validity of the Kinect system, relative to the VICON three-dimensional system which is considered as the gold standard for motion analysis, to measure trunk and pelvis alignment during single leg stance. To investigate the discriminant validity of the Kinect system between with and without hip disorders.
Methods:
For evaluation of the concurrent validity of the Kinect system, the intra-class correlation coefficient (ICC (3,1)) was calculated for the angle of inclination of the pelvis and trunk in 5 healthy individuals. For evaluation of the discriminant validity of the Kinect system, the angle of inclination of the pelvis and trunk during single leg stance were measured in 27 individuals with hip disorders and 100 healthy individuals. Differences in the maximum angle of inclination of the pelvis and trunk were evaluated between hip disorders and healthy individuals using the Mann-Whitney U test.
Results:
ICC values were between 0.83-0.93 for the pelvic and 0.63-0.81 for the trunk angle, respectively. The maximum trunk inclination angle calculated using the Kinect system was significantly higher in patients with hip disorders than healthy individuals, with no significant between-group difference in the angle of inclination of the pelvis.
Significance:
The Kinect system was adequate to detect certain abnormal movements during single leg stance among patients with hip disorders. Therefore, the Kinect system could provide a convenient motion analysis tool for the assessment of patients with hip disorders.
More Related Videos
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
07:44Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019
Related Concept Videos
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Muscles that Move the Leg
Anterior Compartment
The quadriceps femoris, the most visible muscle of the anterior compartment, is integral for leg extension and thigh flexion. It is formed by merging four distinct muscles — the vastus lateralis, vastus medialis, vastus intermedius, and rectus femoris. The quadriceps tendon, a shared tendon of the four quadriceps muscles, is affixed...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis - Acceleration
Reliability and Validity
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...