Body size and tube voltage-dependent guiding equations for optimal selection of image acquisition parameters in
1Medical Radiation Science, School of Dentistry and Health Sciences, Faculty of Science, Charles Sturt University, Wagga Wagga, NSW, 2678, Australia. xzheng@csu.edu.au.
Abstract:
The purpose of this work was to present body size and tube voltage-dependent equations for optimal selection of image acquisition parameters in guiding clinical X-ray imaging. The dose output of X-ray tubes was expressed as a function of the image acquisition parameters of tube voltage (kVp), tube current-exposure time product (mAs), and body size (d). Dose power (n) to kVp was determined to be a linear function of body size in an earlier phantom study. Tube voltage-dependent attenuation coefficients of water were used to determine the kVp effect on the depth dose of X-rays from the body's entrance surface. The new expression for the dose output of X-ray tubes in patients was then employed for image quality and radiation dose optimization, assuming that image quality is a logistic function of the radiation dose to patients. For constant kVp, the percentage of mAs increase for a 1-cm increase in body size d is dependent on the kVp applied. For constant mAs, the percentage of kVp increase for a 1-cm increase in body size is dependent on both body size d and the kVp applied. For constant body size, the percentage of kVp increase should be a fraction of the percentage of decrease in the mAs, where the fraction is dependent on the body size. The improved body size and tube voltage-dependent governing equations for variations in X-ray imaging parameters should be more accurate in guiding optimal selection of the kVp and mAs image acquisition parameters in medical X-ray imaging.
Related Concept Videos
X-ray Imaging
Frequency-dependent Selection
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Equation of Motion for a Rigid Body
The combined moments generated about the center of mass of the object are equal to the rate of change of the angular momentum of the body. An external force, when applied at a different...
The Nernst Equation
The interconnection between standard cell potentials and various thermodynamic parameters such as the standard free energy change ΔG° and equilibrium constant K has been previously explored. For example, a redox reaction involving zinc(II) and tin(II) ions at 1 M concentration with Eºcell = +0.291 V and ΔG° = −56.2 kJ is spontaneous.