Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Improving Translational Accuracy02:07

Improving Translational Accuracy

3.7K
3.7K
Improving Translational Accuracy02:07

Improving Translational Accuracy

15.0K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
15.0K
Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

17.0K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
17.0K
Brick Cutting Techniques01:08

Brick Cutting Techniques

680
Brick-cutting techniques involve various tools and methods to shape bricks for construction. A mason's hammer with a chisel-pointed end is used for basic shaping through sharp, precise strikes. For more complex shapes requiring higher precision, a power saw with a water-cooled diamond blade is used.
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
680
Key Techniques in Microbiology01:19

Key Techniques in Microbiology

2.5K
Aseptic techniques prevent contamination, ensure experimental accuracy, and protect researchers and microbial cultures. These techniques are essential in clinical, industrial, and research settings where sterility is required.Maintaining Sterility in Laboratory PracticesScientists maintain sterility by sterilizing tools with heat or chemicals, disinfecting work surfaces, and handling cultures in controlled environments. Working near an open flame or within a laminar flow hood reduces the risk...
2.5K
Simple Staining Technique01:24

Simple Staining Technique

4.1K
OverviewStaining techniques in microscopy enhance the visualization of microorganisms by increasing contrast and allowing the differentiation of cellular structures. Simple staining is one of the fundamental methods used to observe the basic morphological characteristics of microorganisms, including their size, shape, and arrangement. This method relies on the application of a single dye to stain the entire cell, producing a clear contrast between the cell and the background.FixationFixation is...
4.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effect of Yoga-Based Interventions on Fatigue, Stress, and Sleep Quality in Pediatric Oncology Patients.

Nigerian journal of clinical practice·2026
Same author

Zalunfiban at First Medical Contact for ST-Elevation Myocardial Infarction.

NEJM evidence·2025
Same author

Comparison of postvoid residual urine volumes among lower urinary tract parameters in pediatric and adolescent age groups: A cohort study at a tertiary referral center.

Actas urologicas espanolas·2025
Same author

High frequency of transient congenital hypothyroidism among infants referred for suspected congenital hypothyroidism from the Turkish National screening program: thyroxine dose may guide the prediction of transients.

Journal of endocrinological investigation·2024
Same author

Tromethamine and dodecanol appear to be the major secondary metabolites of Streptomyces decoyicus M.

Archives of microbiology·2022
Same author

Percutaneous left atrial appendage closure reduces cost of care independent of the institutional cumulative caseload in patients with non-valvular atrial fibrillation.

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation·2022

Related Experiment Video

Updated: Feb 11, 2026

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder
06:46

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder

Published on: June 7, 2024

1.4K

Improving the rhinomanometry technique using benzoin tincture.

F Arslan1, Ü Yıldızoğlu2, A Durmaz3

  • 1Department of Otolaryngology, Head and Neck Surgery,Beytepe Murat Erdi Eker State Hospital,Ankara,Turkey.

The Journal of Laryngology and Otology
|April 19, 2018
PubMed
Summary
This summary is machine-generated.

Using benzoin tincture for nasal skin preparation significantly improves anterior rhinomanometry. This method enhances foam tape adhesion, reducing procedure time and increasing test reliability for faster evaluations.

Keywords:
Airway ResistanceBenzoinData AccuracyRhinomanometry

More Related Videos

Author Spotlight: Advancing Prostate Cancer Research Through Improved Tissue Sampling and Biobanking
07:34

Author Spotlight: Advancing Prostate Cancer Research Through Improved Tissue Sampling and Biobanking

Published on: November 17, 2023

1.2K
Piezo High Accuracy Surgical Osteal Removal PHASOR: A Technique for Improved Cranial Window Surgery in Mice
06:09

Piezo High Accuracy Surgical Osteal Removal PHASOR: A Technique for Improved Cranial Window Surgery in Mice

Published on: March 2, 2018

11.1K

Related Experiment Videos

Last Updated: Feb 11, 2026

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder
06:46

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder

Published on: June 7, 2024

1.4K
Author Spotlight: Advancing Prostate Cancer Research Through Improved Tissue Sampling and Biobanking
07:34

Author Spotlight: Advancing Prostate Cancer Research Through Improved Tissue Sampling and Biobanking

Published on: November 17, 2023

1.2K
Piezo High Accuracy Surgical Osteal Removal PHASOR: A Technique for Improved Cranial Window Surgery in Mice
06:09

Piezo High Accuracy Surgical Osteal Removal PHASOR: A Technique for Improved Cranial Window Surgery in Mice

Published on: March 2, 2018

11.1K

Area of Science:

  • Otolaryngology
  • Respiratory Medicine
  • Medical Devices

Background:

  • Anterior rhinomanometry is a key diagnostic tool for nasal airflow.
  • Traditional foam tape application can be time-consuming and prone to slippage.
  • Improving the reliability and efficiency of rhinomanometry is clinically important.

Purpose of the Study:

  • To evaluate the efficacy of benzoin tincture in enhancing anterior rhinomanometry.
  • To determine if benzoin tincture application improves foam tape adhesion and test consistency.

Main Methods:

  • A comparative study design was employed.
  • Anterior rhinomanometry was performed on subjects with and without prior nasal skin preparation using benzoin tincture.
  • Foam tape adhesion and procedure duration were primary outcome measures.

Main Results:

  • The average time for anterior rhinomanometry without benzoin tincture was 281.32 seconds.
  • With benzoin tincture, the average procedure time decreased to 121.24 seconds.
  • Coefficients of variation improved significantly from ~7.5% to ~2.2% with benzoin tincture.

Conclusions:

  • Benzoin tincture significantly reduces the duration of anterior rhinomanometry.
  • The use of benzoin tincture enhances foam tape adhesion, leading to greater test reliability.
  • This simple preparation method offers a faster and more dependable rhinomanometric evaluation.