An integrative approach combining passive sampling, bioassays, and effect-directed analysis to assess the impact of
Manoj Sonavane1, Jennifer E Schollée2,3, Anita O Hidasi2,4
1Institut National de l'Environnement Industriel et des risques (INERIS), Verneuil-en-Halatte, France.
Abstract:
Wastewater treatment plant (WWTP) effluents are major sources of endocrine-disrupting chemicals (EDCs) and other chemicals of toxicological concern for the aquatic environment. In the present study, we used an integrated strategy combining passive sampling (Chemcatcher®), developmental toxicity, and mechanism-based in vitro and in vivo bioassays to monitor the impacts of a WWTP on a river. In vitro screening revealed the WWTP effluent as a source of estrogen, glucocorticoid, and aryl hydrocarbon (AhR) receptor-mediated activities impacting the downstream river site where significant activities were also measured, albeit to a lesser extent than in the effluent. Effect-directed analysis of the effluent successfully identified the presence of potent estrogens (estrone, 17α-ethinylestradiol, and 17β-estradiol) and glucocorticoids (clobetasol propionate and fluticasone propionate) as the major contributors to the observed in vitro activities, even though other unidentified active chemicals were likely present. The impact of the WWTP was also assessed using zebrafish embryo assays, highlighting its ability to induce estrogenic response through up-regulation of the aromatase promoter-dependent reporter gene in the transgenic (cyp19a1b-green fluorescent protein [GFP]) zebrafish assay and to generate teratogenic effects at nonlethal concentrations in the zebrafish embryo toxicity test. The present study argues for the use of such an integrated approach, combining passive sampling, bioassays, and effect-directed analysis, to comprehensively identify endocrine active compounds and associated hazards of WTTP effluents. Environ Toxicol Chem 2018;37:2079-2088. © 2018 SETAC.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
10:53Concentration of Virus Particles from Environmental Water and Wastewater Samples Using Skimmed Milk Flocculation and Ultrafiltration
Published on: March 17, 2023
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Impact of Groups on Groups
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Impact
When particles with different initial velocities collide, they induce deformation by applying equal and opposite impulses. At the point of maximum deformation, the particles move together with...
