Abstract:
A 74-year-old man presented with progressive dyspnea on exertion. History included peripheral arterial disease and coronary artery bypass grafting with aortic valve replacement 12 years ago. Subsequently, the surgical valve developed severe stenosis and moderate insufficiency. He underwent a transapical valve-in-valve transcatheter aortic valve replacement 5 years before presentation. This second valve developed a mean gradient of 66 mm Hg with mild insufficiency. The patient was treated with a third aortic valve using an alternative transcaval approach, significantly alleviating his symptoms.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...