Related Experiment Video
Updated: Feb 11, 2026

Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases
Published on: March 11, 2016
Parametric model fitting-based approach for retinal blood vessel caliber estimation in eye fundus images
Teresa Araújo1,2, Ana Maria Mendonça1,2, Aurélio Campilho1,2
1Faculdade de Engenharia da Universidade do Porto (FEUP), 4200-465 Porto, Portugal.
Background:
Changes in the retinal vessel caliber are associated with a variety of major diseases, namely diabetes, hypertension and atherosclerosis. The clinical assessment of these changes in fundus images is tiresome and prone to errors and thus automatic methods are desirable for objective and precise caliber measurement. However, the variability of blood vessel appearance, image quality and resolution make the development of these tools a non-trivial task.
Metholodogy:
A method for the estimation of vessel caliber in eye fundus images via vessel cross-sectional intensity profile model fitting is herein proposed. First, the vessel centerlines are determined and individual segments are extracted and smoothed by spline approximation. Then, the corresponding cross-sectional intensity profiles are determined, post-processed and ultimately fitted by newly proposed parametric models. These models are based on Difference-of-Gaussians (DoG) curves modified through a multiplying line with varying inclination. With this, the proposed models can describe profile asymmetry, allowing a good adjustment to the most difficult profiles, namely those showing central light reflex. Finally, the parameters of the best-fit model are used to determine the vessel width using ensembles of bagged regression trees with random feature selection.
Results And Conclusions:
The performance of our approach is evaluated on the REVIEW public dataset by comparing the vessel cross-sectional profile fitting of the proposed modified DoG models with 7 and 8 parameters against a Hermite model with 6 parameters. Results on different goodness of fitness metrics indicate that our models are constantly better at fitting the vessel profiles. Furthermore, our width measurement algorithm achieves a precision close to the observers, outperforming state-of-the art methods, and retrieving the highest precision when evaluated using cross-validation. This high performance supports the robustness of the algorithm and validates its use in retinal vessel width measurement and possible integration in a system for retinal vasculature assessment.
Related Concept Videos
Induced-fit Model
Enzymes exhibit substrate specificity, meaning that they can only bind to certain substrates. This is mainly determined by the shape and chemical...
Statistical Methods to Analyze Parametric Data: Student t-Test and Goodness-of-Fit Test
The Student's t-test is a statistical test that examines if there is a statistically significant difference between the means of two groups. This test is instrumental when dealing with...
Anatomy of Blood Vessels
Arteries
Arteries circulate oxygenated blood from the heart, except the pulmonary artery, which transports deoxygenated blood to the lungs. Large arteries, such as the aorta,...
Structure of Blood Vessels
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...
Overview of Blood Vessels
Arteries and Arterioles: Arteries are muscular and elastic vessels that primarily carry oxygenated blood from the heart to body tissues, except for the pulmonary artery, which carries deoxygenated blood. They have thick walls to withstand high pressure and contain a layer of muscle tissue, allowing them to expand or contract as...

