Spatial registration of neuron morphologies based on maximization of volume overlap

Ajayrama Kumaraswamy1, Kazuki Kai2, Hiroyuki Ai2

  • 1Department of Biology II, Ludwig-Maximilians-Universität München, Grosshadernerstr, 2, Planegg-Martinsried, 82152, Germany. ajayramak@bio.lmu.de.

BMC Bioinformatics
|April 20, 2018
PubMed
Abstract

Related Concept Videos

¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.6K
Microbial Morphologies01:29

Microbial Morphologies

Bacterial and archaeal cells exhibit remarkable diversity in shape and structure, critical in their adaptability and functionality. Among bacteria, the most commonly observed shapes include cocci and bacilli. Cocci are spherical and may exist singly or in groupings such as pairs (diplococci), chains (streptococci), clusters (staphylococci), or tetrads. Bacilli, in contrast, are rod-shaped and can also occur as single cells, in pairs, or chains, depending on their environmental and genetic...
4.1K
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.8K
Volume of Distribution01:20

Volume of Distribution

The apparent volume of distribution (Vd) is a crucial pharmacokinetic parameter representing the hypothetical body fluid volume into which a drug disperses. It is calculated based on the total amount of drug in the body (estimated from the administered dose and bioavailability) divided by the plasma drug concentration. The total amount of drug in the body does not directly refer to the dose given but is derived by accounting for absorption, distribution, metabolism, and excretion processes.
1.3K
Problem Solving: Volume01:13

Problem Solving: Volume

The volume of a fuel tank mounted on the wing of a jet aircraft can be modeled using the concept of solids of revolution. In this case, the tank is formed by rotating a two-dimensional region, defined by a mathematical function, about the x-axis. The region extends along the axis from zero to two meters, and the resulting three-dimensional shape is symmetric about the axis of rotation. Because the boundary curve lies directly against the axis, the disk method is an appropriate technique for...
86
Respiratory Volumes01:15

Respiratory Volumes

Respiratory volumes are crucial metrics, meticulously measured to quantify the air exchanged in and out of the lungs during various phases of the breathing cycle. These precise measurements are vital for assessing lung function, diagnosing respiratory conditions, and monitoring overall respiratory health. Each parameter provides specific insights into the mechanics of breathing and the functional capacity of the lungs.
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
3.0K