Related Experiment Video
Updated: Feb 11, 2026

Anterior Cervical Discectomy and Fusion in the Ovine Model
Published on: October 5, 2009
Is a patient-specific drill template via a cortical bone trajectory safe in cervical anterior transpedicular
Peng Peng1, Yafei Xu2, Xintao Zhang3
1Department of Anatomy, Guangdong Provincial Key Laboratory of Medical Biomechanics, School of Basic Medical Sciences, Southern Medical University, 1063 Shatai Nan Road, Baiyun District, Guangzhou, Guangdong, China.
Background:
This study aimed to develop patient-specific drill templates by computer numerical control or three-dimensional printing via two cortical bone trajectories (CBTs) and to evaluate their efficacies and accuracies in cervical anterior transpedicular insertion.
Methods:
Preoperative CT images of 20 cadaveric cervical vertebrae (C3-C7) were obtained. After image processing, patient-specific drill templates were randomly assigned to be constructed via two CBTs (CBT0 and CBT0.7) and manufactured by two methods (computer numerical control and three-dimensional printing). Guided by patient-specific drill templates, 3.5-mm-diameter screws were inserted into the pedicles. Postoperative CT scans were performed to evaluate the screw deviation in the entry point and midpoint of the pedicle. The screw positions were also graded.
Results:
Computer numerical control patient-specific drill templates had a significantly shorter manufacturing time compared to three-dimensional-printed patient-specific drill templates (p < 0.01). Absolute deviations at the entry point and midpoint of the pedicle had no significant differences on the transverse and sagittal planes (p > 0.05). There were no significant differences in screw positions (p = 0.3). However, three screw positions were in grade 3 in CBT0, while the others were in grade 1.
Conclusions:
CBT0.7 appears to be a safe and feasible trajectory for cervical anterior transpedicular insertion. Bio-safe computer numerical control patient-specific drill templates can facilitate cervical anterior transpedicular insertion with good feasibility and accuracy.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
09:00Investigating the Function of Deep Cortical and Subcortical Structures Using Stereotactic Electroencephalography: Lessons from the Anterior Cingulate Cortex
Published on: April 15, 2015
Related Concept Videos
Orthogonal Trajectories
DNA as a Genetic Template
DNA as a Genetic Template
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Muscles of the Anterior Neck
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...