Related Experiment Video
Updated: Feb 11, 2026

Brain Death Induction in Mice Using Intra-Arterial Blood Pressure Monitoring and Ventilation via Tracheostomy
Published on: April 17, 2020
High-riding brachiocephalic (innominate) artery during surgical tracheostomy
Hatem Ahmad Dalati1, Muhammad Sami Jabbr1, Jamal Kassouma1
1ENT, Dubai Hospital, Dubai Health Authority, Dubai, United Arab Emirates.
Abstract:
Two cases of a high-riding innominate artery, which were found during routine surgical tracheostomy. A cartilage flap was applied to cover the significant vessel to prevent the life-threatening complications. These two cases were followed up for 2 months without any adverse events. We discussed the related vascular anatomy, imaging studies and brief literature review.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning II: Procedure
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...