Related Experiment Video
Updated: Feb 11, 2026

Gold Nanoparticle Synthesis
Published on: July 10, 2021
Making strong polyelectrolyte brushes pH-sensitive by incorporation of gold nanoparticles
D Boyaciyan1, P Krause, R von Klitzing
1Soft Matter at Interfaces, Technische Universität Darmstadt, Alarich-Weiss-Straße 10, 64287 Darmstadt, Germany. klitzing@fkp.tu-darmstadt.de.
Abstract:
Doping polymer brushes with gold nanoparticles (AuNPs) results in composite materials with colorimetric sensor properties. The present paper addresses the effect of electrostatic particle-particle interaction and the effect of the polymer brush type on particle assembly formation within the polymer matrix. The prospect for long-term use as colorimetric sensors is tested. Therefore, two different types of brushes of pH-insensitive polymers, non-ionic poly(N-isopropylacrylamide) (PNIPAM) and cationic poly-[2-(methacryloyloxy)ethyl] trimethylammonium chloride (PMETAC), are studied. After incubation of the non-ionic PNIPAM brush in an aqueous suspension of AuNPs with a pH-sensitive carboxylic acid capping, hydrogen binding led to attachment of the AuNPs, but they were easily detached at high pH due to loss of the hydrogen binding. In contrast, the anionic AuNPs adhere well to cationic PMETAC brushes even after post-treatment at low pH where the charge density of the AuNPs is strongly reduced. Therefore, the PMETAC/AuNP composites were further tested with respect to their stability against pH variations and their impact for colorimetric sensors. Although the neat PMETAC brush is not pH-sensitive, after embedding pH-sensitive AuNPs, the PMETAC/AuNP composite becomes pH-sensitive in a reversible manner. This is detectable by the reversible shift of the plasmon band and the reversible thickness change of the composites by exposing them to different pH.
Related Concept Videos
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Titration of a Weak Acid with a Strong Base

