Related Experiment Video
Updated: Feb 11, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Molecularly imprinted polymer for determination of lumefantrine in human plasma through chemometric-assisted
Pedro Henrique Reis da Silva1, Melina Luiza Vieira Diniz1, Gerson Antônio Pianetti1
1Laboratório de Controle de Qualidade de Medicamentos e Cosméticos, Departamento de Produtos Farmacêuticos, Faculdade de Farmácia, Universidade Federal de Minas Gerais, Avenida Antônio Carlos, 6627, Pampulha, Belo Horizonte, MG 31270-901, Brazil.
Abstract:
Lumefantrine is the first-choice treatment of Falciparum uncomplicated malaria. Recent findings of resistance to lumefantrine has brought attention for the importance of therapeutic monitoring, since exposure to subtherapeutic doses of antimalarials after administration is a major cause of selection of resistant parasites. Therefore, this study focused on the development of innovative, selective, less expensive and stable molecularly imprinted polymers (MIPs) for solid-phase extraction (SPE) of lumefantrine from human plasma to be used in drug monitoring. Polymers were synthesized by precipitation polymerization and chemometric tools (Box-Behnken design and surface response methodology) were employed for rational optimization of synthetic parameters. Optimum conditions were achieved with 2-vinylpyridine as monomer, ethylene glycol dimethacrylate as crosslinker and toluene as porogen, at molar ratio of 1:6:30 of template/monomer/crosslinker and azo-bisisobutyronitrile as initiator at 65 °C. The MIP obtained was characterized and exhibited high thermal stability, adequate surface morphology and porosity characteristics and high binding properties, with high affinity (adsorption capacity of 977.83 μg g-1) and selectivity (imprinting factor of 2.44; and selectivity factor of 1.48 and selectivity constant of 1.44 compared with halofantrine). Doehlert matrix and fractional designs were satisfactorily used for development and optimization of a MISPE-HPLC-UV method for determination of lumefantrine. The method fulfilled all validation parameters, with recoveries ranging from 83.68% to 85.42%, and was applied for quantitation of the drug in plasma from two healthy volunteers, with results of 1407.89 and 1271.35 ng mL-1, respectively. Therefore, the MISPE-HPLC-UV method optimized through chemometrics provided a rapid, highly selective, less expensive and reproducible approach for lumefantrine drug monitoring.
More Related Videos
13:42Solid-phase Submonomer Synthesis of Peptoid Polymers and their Self-Assembly into Highly-Ordered Nanosheets
Published on: November 2, 2011
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Related Concept Videos
Molecular Comparison of Gases, Liquids, and Solids
Molecular and Ionic Solids
Molecular Solids
Molecular crystalline solids, such as ice, sucrose (table sugar), and iodine, are solids that are composed of neutral molecules as their constituent units. These molecules are held together by weak intermolecular forces such as London dispersion forces, dipole-dipole interactions, or hydrogen bonds, which...
Imprinting
Genomic Imprinting and Inheritance
The expression of some genes depends on which parent passed the gene to the offspring, through a phenomenon known as...
Speed of Sound in Solids and Liquids
Polymers: Defining Molecular Weight
The number average molecular weight (Mn) is the summation of the number...