Related Experiment Video
Updated: Feb 11, 2026

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
Quantification of liver iron concentration using the apparent susceptibility of hepatic vessels
Saifeng Liu1, Chaoyue Wang2, Xiaoqi Zhang3
1The MRI Institute for Biomedical Research, Bingham Farms, MI, USA.
Background:
The quantification of liver iron concentration (LIC) is important for the monitoring of the body iron level in patients with iron overload. Conventionally, LIC is quantified through R2 or R2* mapping using MRI. In this paper, we demonstrate an alternative approach for LIC quantification through measuring the apparent susceptibility of hepatic vessels using quantitative susceptibility mapping (QSM).
Methods:
QSM was performed in the liver region with the iterative susceptibility weighted imaging and mapping (iSWIM) algorithm, using the geometry of the vessels extracted from magnitude images as constraints. The susceptibilities of liver tissue were estimated from the apparent susceptibility of the hepatic veins and then converted to LIC. The accuracy of the proposed method was first validated using simulations, and then confirmed using in vivo data collected on 8 healthy controls and 11 patients at 3T. The effects of data acquisition parameters were studied using simulations, and the LICs estimated using QSM were compared with those estimated using R2* mapping.
Results:
Simulation results showed that the use of a 3D data acquisition protocol with higher image resolution led to improved accuracy in LIC quantification using QSM. Both simulations and in vivo data results demonstrated that the LICs estimated using the proposed QSM method agreed well with those estimated using R2* mapping. With the shortest echo time being 2.5ms in the multi-echo gradient echo sequence, simulations results showed that LIC up to 12.45 mg iron/g dry tissue can be quantified using the proposed QSM method. For the in vivo data, the highest LIC measured was 11.32 mg iron/g dry tissue.
Conclusions:
The proposed method offers a reliable and flexible way to quantify LIC and has the potential to extend the range of LIC that can be accurately measured using R2* and QSM.
Related Concept Videos
Apparent Weight
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Apparent Weight and the Earth's Rotation
For an object on the Earth's equator, the net centripetal force that accounts for its rotation is the Earth's pull towards its center, or the weight minus the normal force that prevents it from piercing into the Earth's surface....
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Concentration Cells
Consider the following voltaic cell:
Susceptibility, Permittivity and Dielectric Constant

