Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
Highly sensitive and specific electrochemical biosensor for microRNA-21 detection by coupling catalytic hairpin
Qing Li1, Fanpeng Zeng, Nan Lyu
1Xuzhou Central Hospital, Xuzhou, Jiangsu 221004, China. lyunan8833@sina.com mwlj521@163.com.
Background:
MicroRNA plays a significant role in gene regulation and is usually regarded as an important biological marker. Electrochemical biosensors are excellent tools for microRNA detection.
Methods:
In this experiment, we take miRNA-21 as a target, combining catalytic hairpin assembly (CHA) and rolling circle amplification (RCA) as a dual signal amplification strategy for the detection of microRNA in an electrochemical biosensor.
Results:
This strategy has a good linear range of 0.5-12 500 pmol of microRNA. The limit of detection (LOD) for miRNA is as low as 290 fmol, showing excellent performance. Finally, this method has been successfully applied to the detection of miRNA-21 from HeLa cells.
Conclusion:
This method can be applied not only for microRNA detection with high sensitivity and speed, but can also detect small molecules and proteins combined with aptamers.
More Related Videos
10:13Simple and Fast Rolling Circle Amplification-Based Detection of Topoisomerase 1 Activity in Crude Biological Samples
Published on: December 2, 2022
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Related Concept Videos
MicroRNAs
MicroRNAs
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Circles
Rolling Without Slipping