Related Experiment Video
Updated: Feb 11, 2026

High-throughput Screening for Chemical Modulators of Post-transcriptionally Regulated Genes
Published on: March 3, 2015
Truncated aptamers for total and glycated hemoglobin, and their integration into a graphene oxide-based fluorometric
Abrar Yousef Almusharraf1, Shimaa Eissa1, Mohammed Zourob2,3
1Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh, 11533, Saudi Arabia.
Abstract:
The authors describe the identification of an effective binding region of aptamers against glycated (HbA1c) and total haemoglobin (tHb) by using a fluorometric assay. Truncation of the originally selected aptamers from 60 to 46 and 34 nucleotides for HbA1c and tHb, respectively, enhances the affinity for their targets. Moreover, shortening the aptamer sequences leads to a better conformational change after target binding which enabled the integration of the aptamers in a graphene oxide (GO)-based fluorometric assay. First, fluorescein-labelled truncated aptamers were physically absorbed onto the surface of GO surface via π-stacking interaction. This leads to quenching of fluorescence. Once the truncated aptamers bind the target protein, a conformational change is induced which results (a) )in the release of the aptamers from the surface of GO and (b) in the restoration of green fluorescence that is measured at 515 nm. The assay can be carried out in a microtiter plate format in homogeneous solution, this avoiding the steps of immobilization, incubation, and washing that are often necessary in immunoassays. This also reduces the time and the costs of the overall assay and allows for high throughput screening for diabetes. HbA1c can be detected in the range from 5.4 to 10.6%. The assay is selective for HbA1c over other proteins that commonly exist in blood. The results obtained by using this method compare well with those of a turbidimetric immunoassay that is typically applied in clinical laboratories. Graphical abstract Truncated aptamers for total and glycated hemoglobin were selected and integrated into a graphene oxide-based fluorescence detection assay for high-throughput screening for diabetes.
More Related Videos
07:37Click-Chemistry Based Fluorometric Assay for Apolipoprotein N-acyltransferase from Enzyme Characterization to High-Throughput Screening
Published on: May 13, 2020
06:50A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases
Published on: May 29, 2020
Related Concept Videos
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...
Truncation in Survival Analysis
Left truncation occurs when individuals who experienced the event of interest before a certain time are not included in the study. This is often due to a "delayed entry" into the study where only those who survive until a certain entry point are...
Oxidation Numbers
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...