Purpose:
Self-expandable stents have enabled endovascular treatment of wide-necked aneurysms (ordinarily viewed as technically prohibitive), with favorable outcomes. However, the impact of stent type on occlusive stability has not been adequately investigated. In small-sized unruptured saccular aneurysms, we generated estimates of stent-assisted coil embolization outcomes during follow-up monitoring. Stent type and other risk factors linked to recanalization were analyzed.
Methods:
A cohort of 286 patients harboring 312 small-sized unruptured aneurysms (< 10 mm) was subjected to mid-term and extended follow-up monitoring after stent-assisted coiling. Three types of stents (Enterprise, 192; Neuroform, 27; LVIS, 93) were deployed in this population; all medical records and radiologic data of which were reviewed. Mid-term recanalization rates and related risk factors were assessed using binary logistic regression analysis.
Results:
A total of 49 aneurysms (15.7%) displayed recanalization at 6 months postembolization, with 34 and 15 instances of minor and major recanalization, respectively. Multivariate analysis indicated that wide-necked aneurysms (> 4 mm) (HR = 2.362; p = 0.017), incomplete occlusion at time of coiling (HR = 2.949; p = 0.002), and stent type (p = 0.048) were significant factors in mid-term recanalization, whereas hypertension (p = 0.095) and packing density ≤ 30% (p = 0.213) fell short of statistical significance. Compared with Enterprise (HR = 2.828) or Neuroform (HR = 4.206) stents, outcomes proved more favorable with use of LVIS.
Conclusions:
Above findings demonstrate that in addition to occlusive status at time of coil embolization and neck size, stent type may affect follow-up outcomes of stent-assisted coil embolization in small-sized aneurysms. LVIS (vs Enterprise or Neuroform stents) performed best during follow-up monitoring in terms of limiting recanalization.
Related Concept Videos
Types of Impact
The coefficient of restitution is a metric for understanding the dynamics of impacts. It quantifies the ratio of relative velocity...
Pulmonary Embolism I: Introduction
Predicting Reaction Outcomes
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
Impact of Groups on Groups
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...