Related Experiment Video
Updated: Feb 11, 2026

Transpupillary-Guided Trans-Scleral Transplantation of Subretinal Grafts in a Retinal Degeneration Mouse Model
Published on: January 26, 2024
Fluorine Grafted Cu7S4-Au Heterodimers for Multimodal Imaging Guided Photothermal Therapy with High Penetration Depth
Jiabin Cui1, Rui Jiang1, Chang Guo1
1State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering , Beijing University of Chemical Technology , Beijing 100029 , China.
Abstract:
We report the multifunctional nanocomposites (NCs) consisting of 19F-moieties grafted Cu7S4-Au nanoparticles (NPs) for negligible background 19F-magnetic resonance imaging (19F-MRI) and computed tomography (CT) imaging guided photothermal therapy. The localized surface plasmon resonance (LSPR) absorption can be reasonably tuned to the in vivo transparent window (800-900 nm) by coupling Au (<10 nm, LSPR ∼530 nm) with Cu7S4 (<15 nm, LSPR ∼1500 nm) into Cu7S4-Au heterodimers. The in vivo photothermal tests show that Cu7S4-Au show deeper light penetration with 808 nm irradiation, better photothermal efficacy, and less damage to normal tissues than Cu7S4 with 1500 nm irradiation. Moreover, compared to traditional 1H-MRI, the 19F-MRI based on these NCs demonstrates much better sensitivity due to the negligible background. This work offers a promising strategy for multimodal imaging guided photothermal therapy of deep tissue with good efficacy.
More Related Videos
09:51One Minute, Sub-One-Watt Photothermal Tumor Ablation Using Porphysomes, Intrinsic Multifunctional Nanovesicles
Published on: September 17, 2013
06:42Plasmonic Photothermal Cancer Therapy: Nanoparticle-embedded Tumor-tissue-mimicking Phantoms for Visualizing Photothermal Temperature Distribution
Published on: May 9, 2025
Related Concept Videos
Uniform Depth Channel Flow
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene
Depth Perception and Spatial Vision
Uniform Depth Channel Flow: Problem Solving
Gene Therapy
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: