Related Experiment Video
Updated: Feb 11, 2026

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Small Left Ventricular Size Is an Independent Risk Factor for Ventricular Assist Device Thrombosis
Venkat Keshav Chivukula1, Jennifer A Beckman2, Anthony R Prisco3
1From the Department of Mechanical Engineering.
Abstract:
The prevalence of ventricular assist device (VAD) therapy has continued to increase due to a stagnant donor supply and growing advanced heart failure (HF) population. We hypothesize that left ventricular (LV) size strongly influences biocompatibility and risk of thrombosis. Unsteady computational fluid dynamics (CFD) was used in conjunction with patient-derived computational modeling and virtual surgery with a standard, apically implanted inflow cannula. A dual-focus approach of evaluating thrombogenicity was employed: platelet-based metrics to characterize the platelet environment and flow-based metrics to investigate hemodynamics. Left ventricular end-diastolic dimensions (LVEDds) ranging from 4.5 to 6.5 cm were studied and ranked according to relative thrombogenic potential. Over 150,000 platelets were individually tracked in each LV model over 15 cardiac cycles. As LV size decreased, platelets experienced markedly increased shear stress histories (SHs), whereas platelet residence time (RT) in the LV increased with size. The complex interplay between increased SH and longer RT has profound implications on thrombogenicity, with a significantly higher proportion of platelets in small LVs having long RT times and being subjected to high SH, contributing to thrombus formation. Our data suggest that small LV size, rather than decreased VAD speed, is the primary pathologic mechanism responsible for the increased incidence of thrombosis observed in VAD patients with small LVs.
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Introduction to Test of Independence
The test statistic for a test of independence is similar to that of a goodness-of-fit test:
Hypothesis Test for Test of Independence
H0: The two variables (factors)...
Venous Thrombosis I: Introduction