Related Experiment Video
Updated: Feb 11, 2026

Design and Implementation of an fMRI Study Examining Thought Suppression in Young Women with, and At-risk, for Depression
Published on: May 19, 2015
Strength of continuous flash suppression is optimal when target and masker modulation rates are matched
1School of Psychology, University of Sydney, Sydney, Australia.
Abstract:
Continuous flash suppression (CFS) is a popular technique whereby a dynamic sequence of Mondrian patterns is presented to one eye in order to suppress a static target presented to the other eye. Although the effectiveness of CFS is generally assumed to increase with the flicker rate of the Mondrian masker, a recent study has shown that suppression is optimal at very low masker rates for sustained targets, but higher rates may be necessary for transient targets. Here we vary the modulation rates of the masker and target using temporally filtered dynamic noise, which allowed us to examine the relationship between target and masker frequency and its effect on suppression strength. Using these carefully controlled, temporally narrowband stimuli, we demonstrate a pattern of results showing that suppression is greatest when target and masker modulate at similar frequencies. This finding indicates the involvement of early temporal-frequency-tuned filters underlying CFS and is consistent with many existing findings in the CFS literature. We also find that these temporally selective processes are orientation selective, which points to an early cortical substrate such as neurons in primary visual cortex. Overall, our study reveals that CFS suppression can be maximized by carefully matching the masker and target in temporal frequency and orientation. More generally, we show the importance of using carefully controlled stimuli for elucidating the underlying mechanisms of CFS. This approach is important at a theoretical level, as it will enable comparison of CFS with existing models of binocular rivalry and interocular suppression and facilitate a unified explanatory framework.
Related Concept Videos
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
The Equilibrium Binding Constant and Binding Strength
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete

