Related Experiment Video
Updated: Feb 11, 2026

Genetic and Biochemical Approaches for In Vivo and In Vitro Assessment of Protein Oligomerization: The Ryanodine Receptor Case Study
Published on: July 27, 2016
Detection of Dimethyl Methylphosphonate (DMMP) Using Polyhedral Oligomeric Silsesquioxane (POSS)
Young-Jun Lee1, Jong-Gyu Kim1, Joo-Hyung Kim1
1Department of Mechanical Engineering, Inha University, Incheon 22212, South Korea.
Abstract:
The detection and monitoring of colorless and odorless chemical warfare agents (CWAs) has become important due to the increasing threat of terrorist activities. To enhance the sensitivity and selectivity of CWAs a number of sensing materials have been developed, including the widely used polyvinylidene fluoride (PVDF). However, PVDF is limited by its low sensitivity and selectivity for many CWAs. In this study, polyhedral oligomeric silsesquioxane (POSS) was used as a sensing material for dimethyl methylphosphonate (DMMP) a simulant of sarin nerve gas. Sensitivity, selectivity, and reusability were investigated with an AT-cut 5 MHz quartz crystal microbalance. At room temperature, POSS exhibited a strong response for DMMP vapor at different concentrations from 20 ppm to 120 ppm leading to fast chemical adsorption and desorption. To investigate selectivity the volatile organic compounds (VOCs) ethanol, water, toluene, ACN, methanol, and n-hexane were tested at a fixed flow rate. Targeted VOCs showed lower responses than DMMP as measured with a quartz crystal microbalance (QCM) sensor, demonstrating the high selectivity of the method. POSS can be considered a potentially useful material for sensing nerve simulants.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...