C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
The pedicle instrumentation and percutaneous elevation (Pi.Pe): a new cementless surgical technique in type A
Andrea Piazzolla1, Giuseppe Solarino2, Davide Bizzoca2
1Orthopaedic, Trauma and Spine Unit, Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, AOU Policlinico Consorziale, University of Bari "Aldo Moro", Piazza Giulio Cesare 11, 70100, Bari, Italy. dott.piazzolla@gmail.com.
Purpose:
To investigate if bone substitutes are strictly necessary to restore the vertebral body height and improve the clinical outcome, in patients with thoracolumbar or lumbar AO type A post-traumatic vertebral fractures, managed with balloon kyphoplasty combined with posterior screw and rod system.
Methods:
105 patients with post-traumatic thoracolumbar spine fracture were recruited. At baseline, the patients underwent a CT and an MRI of the spine. Clinical evaluation was performed, using the Visual Analog Scale (VAS) and the Oswestry Disability Index (ODI), at baseline, 48 h after surgery, at 3-month follow-up (FU), 6-month FU, 48 h after the instrumentation removal and at 24-month FU. At each FU, VK, regional kyphosis (RK), central wall (MH/PH) and anterior wall (AH/PH) heights were assessed on lateral spine X-rays. At 6-month FU, a CT scan of the spine was performed to investigate the fracture healing. The posterior instrumentation was removed 7 months after surgery (range 6-10 months).
Results:
A significant reduction of mean VAS (p < 0.05) and ODI (p < 0.05) was observed after surgery; no impairment of these scores was observed after the instrumentation removal. A significant correction of VK, RK, AH/PH and MH/PH was recorded after surgery; no significant changes of these values were noticed at subsequent FU. After the instrumentation removal, only an RK impairment was recorded, but it was not significant.
Conclusions:
PMMA or bone substitutes are not necessary to keep the reduction of the endplate obtained with the balloon tamp, when BK is performed in the association with posterior percutaneous pedicle screws instrumentation. These slides can be retrieved under Electronic Supplementary Material.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
08:42A Reproducible Cartilage Impact Model to Generate Post-Traumatic Osteoarthritis in the Rabbit
Published on: November 21, 2023
Related Concept Videos
Post-traumatic Stress Disorder
Symptoms and Behavioral Manifestations
A spectrum of distressing symptoms characterizes PTSD. Recurrent flashbacks, where individuals involuntarily relive traumatic events,...
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Muscles of the Vertebral Column
Superficial Layer:
The superficial layer consists primarily of the splenius muscles, which include the splenius capitis and splenius cervicis. These muscles are mainly responsible for the head and cervical spine movements, including extension, rotation, and lateral bending. The splenius capitis...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers