Effect of echo time and T2-weighting on GRASE-based T1w/T2w ratio measurements at 3T
Md Nasir Uddin1, Teresa D Figley1, Chase R Figley2
1Department of Radiology, University of Manitoba, Winnipeg, MB, Canada; Division of Diagnostic Imaging, Health Sciences Centre, Winnipeg, MB, Canada; Neuroscience Research Program, Kleysen Institute for Advanced Medicine, Winnipeg, MB, Canada.
Abstract:
Tissue contrast can be enhanced by dividing T1-weighted (T1w) images by T2-weighted (T2w) images to map the so-called T1w/T2w ratio, which has become an increasingly popular technique for quantifying brain tissue changes associated with neurodevelopment, aging, and a variety of neurodegenerative diseases. However, although it is self-evident that T1w/T2w ratios increase with the amount of T2-weighting in the T2w image - which is determined by the echo time (TE), all else being equal - longer TEs also reduce the signal-to-noise ratio (SNR) of the T2w images, and it is not clear how these SNR characteristics affect the reliability of T1w/T2w measurements. Therefore, the current study systematically investigated how different amounts of T2-weighting affected T1w/T2w measurements in order to determine whether there is an optimal amount of T2-weighting. T1w images were acquired from 10 neurologically healthy adults using a 3D turbo field echo (TFE) sequence, and a series of T2-weighted images were extracted from a multi-echo 3D combined gradient- and spin-echo (GRASE) sequence. Analyses of 12 anatomically defined brain regions revealed that both the mean and standard deviation of the T1w/T2w measurements increased exponentially with TE of the T2w images, and that T2w images with TE ≈ 120-160 ms yielded the most consistent/reproducible contrast between white matter ROIs and the whole-brain T1w/T2w signal. Furthermore, comparisons between T1w/T2w measurements and multi-component T2-relaxation myelin water fractions (MWFs) in the same brain regions revealed that T2w images with TE ≥ 160 ms drastically reduced the degree of correlation between T1w/T2w measurements and MWF. Overall, these findings suggest that: 1) there is a substantial trade-off between increased T1w/T2w contrast (based on longer TEs for the T2w images) and the reliability of quantitative T1w/T2w signals; and 2) the optimal TE for T2w GRASE scans is between 120 ms and 160 ms for calculating T1w/T2w ratios.
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Poisson's Ratio
Odds Ratio
Hazard Ratio
For example, in a clinical trial...