Vertebral Bone Mineral Density Measured by Quantitative Computed Tomography With and Without a Calibration Phantom: A

Josephine Therkildsen1, Jesper Thygesen2, Simon Winther3

  • 1Department of Internal Medicine, Hospital Unit West, Herning, Denmark.

Summary

Quantitative CT bone mineral density (BMD) measurements in chronic kidney disease (CKD) patients showed poor agreement between phantom-less and phantom-based methods. The variability suggests these techniques are not interchangeable for clinical use.

Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
8.9K
Essential Minerals for Bone Health01:31

Essential Minerals for Bone Health

The minerals contained in all of the food we consume are essential for our organ systems. However, certain essential minerals, such as calcium, phosphorus, magnesium, manganese, and fluoride, largely affect bone health.
Calcium and Phosphorus
Calcium is a critical component of bones, especially in the form of calcium phosphate and calcium carbonate. Since the body cannot make calcium, it must be obtained from the diet. However, calcium cannot be absorbed from the small intestine without...
6.6K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
406
Water and Mineral Acquisition02:34

Water and Mineral Acquisition

Specialized tissues in plant roots have evolved to capture water, minerals, and some ions from the soil. Roots exhibit a variety of branching patterns that facilitate this process. The outermost root cells have specialized structures called root hairs that increase the root surface, thus increasing soil contact. Water can passively cross into roots, as the concentration of water in the soil is higher than that of the root tissue. Minerals, in contrast, are actively transported into root cells.
35.9K
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.5K
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
785