Related Experiment Video
Updated: Feb 11, 2026

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
Does ITV vaginal procedure ensure dosimetric coverage during IMRT of post-operative gynaecological tumours without
Ramona Verges1, Alexandra Giraldo1, Alejandro Seoane2
1Radiation Oncology Department, Vall d'Hebron University Hospital, Barcelona, Spain.
Aim:
To find out whether the internal target volume (ITV) vaginal procedure ensures dosimetric coverage during intensity-modulated radiation therapy (IMRT) of post-operative gynaecological tumours without instructions on rectal filling.
Background:
The ITV vaginal procedure does not necessarily include all movements of the bladder, and does not include changes in the rectal volume. We should know if the vaginal ITV is a useful tool in maintaining CTV coverage during treatment.
Materials And Methods:
A retrospective analysis of 24 patients treated between July 2012 and July 2014 with adjuvant IMRT for gynaecological cancer. All patients underwent empty and full bladder CT on simulation (CT-planning) and three weeks later (CT-control). ITV displacement was measured and the 3D vector was calculated. ITV coverage was then evaluated by comparing the volume covered by the prescription isodose on both CT's. Patients were asked to have full bladder but they did not follow recommendations for the rectum.
Results:
The mean 3D vector was 0.64 ± 0.32 cm (0.09-1.30). The mean ITV coverage loss was 5.8 ± 5.7% (0-20.2). We found a significant positive correlation between the 3D vector and the loss of coverage (Pearson correlation, r = 0.493, 95% CI: 0.111-0.748, p = 0.0144). We did not find any significant correlation between the bladder and rectal parameters with the 3D vector and loss of dosimetric coverage. We found a trend between the maximum rectal diameter in CT-planning and 3D vector (r = 0.400, 95% CI: -0.004 to 0.692, p = 0.0529).
Conclusion:
ITV vaginal procedure contributed to ensuring a good dose coverage without instructions on rectal filling.
More Related Videos
05:32Povidone Iodine Rectal Preparation at Time of Prostate Needle Biopsy is a Simple and Reproducible Means to Reduce Risk of Procedural Infection
Published on: September 21, 2015
06:32Operating Procedures of the Electrochemotherapy for Treatment of Tumor in Dogs and Cats
Published on: October 24, 2016
Related Concept Videos
Handwashing III: During the Procedure and Post-Procedure Steps
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Real Number Operations
Operational Amplifiers
Vector Operations
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.