Quantification of Volumetric Bone Mineral Density of Proximal Femurs Using a Two-Compartment Model and Computed
Yan-Lin Liu1,2, Jui-Ting Hsu3, Tian-Yu Shih4
1Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei 11221, Taiwan.
Objectives:
Dual-energy X-ray absorptiometry (DXA) is frequently used to measure the areal bone mineral density (aBMD) in clinical practice. However, DXA measurements are affected by the bone thickness and the body size and are unable to indicate nonosseous areas within the trabecular bone. This study aims to quantify the volumetric bone mineral density (vBMD) using computed tomography (CT) images and the two-compartment model (TCM) methods.
Methods:
The TCM method was proposed and validated by dipotassium phosphate (K2HPO4) phantoms and a standard forearm phantom. 28 cases with DXA scans and pelvic CT scans acquired within six months were retrospectively collected. The vBMD calculated by TCM was compared with the aBMD obtained from DXA.
Results:
For the K2HPO4 phantoms with vBMD ranging from 0.135 to 0.467 g/cm3, the average difference between the real and calculated vBMD was 0.009 g/cm3 and the maximum difference was 0.019 g/cm3. For the standard forearm phantom with vBMD of 0.194, 0.103, and 0.054 g/cm3, the average differences between the real and calculated vBMD were 0.017, 0.014, and 0.011 g/cm3. In the clinical CT image validation, a good linear relationship between vBMD and aBMD was observed with the Pearson correlation coefficient of 0.920 (p < 0.01).
Conclusions:
The proposed TCM method in combination with the homemade cortical bone equivalent phantom provides accurate quantification and spatial distribution of bone mineral content.
More Related Videos
04:24Proper Positioning and Restraint of a Rat Hind Limb for Focused High Resolution Imaging of Bone Micro-architecture Using In Vivo Micro-computed Tomography
Published on: November 22, 2017
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Bones of the Lower Limb: Femur and Patella
Compartment Models: Two-Compartment Model
Essential Minerals for Bone Health
Calcium and Phosphorus
Calcium is a critical component of bones, especially in the form of calcium phosphate and calcium carbonate. Since the body cannot make calcium, it must be obtained from the diet. However, calcium cannot be absorbed from the small intestine without...
Compartment Models: Single-Compartment Model