The Empirical Effect of Gaussian Noise in Undersampled MRI Reconstruction
Patrick Virtue1, Michael Lustig1
1Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA.
Abstract:
In Fourier-based medical imaging, sampling below the Nyquist rate results in an underdetermined system, in which a linear reconstruction will exhibit artifacts. Another consequence is lower signal-to-noise ratio (SNR) because of fewer acquired measurements. Even if one could obtain information to perfectly disambiguate the underdetermined system, the reconstructed image could still have lower image quality than a corresponding fully sampled acquisition because of reduced measurement time. The coupled effects of low SNR and underdetermined system during reconstruction makes it difficult to isolate the impact of low SNR on image quality. To this end, we present an image quality prediction process that reconstructs fully sampled, fully determined data with noise added to simulate the SNR loss induced by a given undersampling pattern. The resulting prediction image empirically shows the effects of noise in undersampled image reconstruction without any effect from an underdetermined system. We discuss how our image quality prediction process simulates the distribution of noise for a given undersampling pattern, including variable density sampling that produces colored noise in the measurement data. An interesting consequence of our prediction model is that recovery from an underdetermined nonuniform sampling is equivalent to a weighted least squares optimization that accounts for heterogeneous noise levels across measurements. Through experiments with synthetic and in vivo datasets, we demonstrate the efficacy of the image quality prediction process and show that it provides a better estimation of reconstruction image quality than the corresponding fully sampled reference image.
More Related Videos
07:30Brain Morphology of Cannabis Users With or Without Psychosis: A Pilot MRI Study
Published on: August 18, 2020
07:33In Vivo Evaluation of Fracture Callus Development During Bone Healing in Mice Using an MRI-compatible Osteosynthesis Device for the Mouse Femur
Published on: November 14, 2017
Related Concept Videos
Gaussian Elimination: Problem Solving
Empirical Method to Interpret Standard Deviation
This rule is used widely in statistics to calculate the proportion of data values...
Reconstruction of Signal using Interpolation
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...