Objective:
Diazepam, administered by the intravenous, oral, or rectal routes, is widely used for the management of acute seizures. Dosage forms for delivery of diazepam by other routes of administration, including intranasal, intramuscular, and transbuccal, are under investigation. In predicting what dosages are necessary to terminate seizures, the minimal exposure required to confer seizure protection must be known. Here we administered diazepam by continuous intravenous infusion to obtain near-steady-state levels, which allowed an assessment of the minimal levels that elevate seizure threshold.
Methods:
The thresholds for various behavioral seizure signs (myoclonic jerk, clonus, and tonus) were determined with the timed intravenous pentylenetetrazol seizure threshold test in rats. Diazepam was administered to freely moving animals by continuous intravenous infusion via an indwelling jugular vein cannula. Blood samples for assay of plasma levels of diazepam and metabolites were recovered via an indwelling cannula in the contralateral jugular vein.
Results:
The pharmacokinetic parameters of diazepam following a single 80-μg/kg intravenous bolus injection were determined using a noncompartmental pharmacokinetic approach. The derived parameters Vd , CL, t1/2α (distribution half-life) and t1/2β (terminal half-life) for diazepam were, respectively, 608 mL, 22.1 mL/min, 13.7 minutes, and 76.8 minutes, respectively. Various doses of diazepam were continuously infused without or with an initial loading dose. At the end of the infusions, the thresholds for various behavioral seizure signs were determined. The minimal plasma diazepam concentration associated with threshold elevations was estimated at approximately 70 ng/mL. The active metabolites nordiazepam, oxazepam, and temazepam achieved levels that are expected to make only minor contributions to the threshold elevations.
Significance:
Diazepam elevates seizure threshold at steady-state plasma concentrations lower than previously recognized. The minimally effective plasma concentration provides a reference that may be considered when estimating the diazepam exposure required for acute seizure treatment.
More Related Videos
09:07Electroconvulsive Seizures in Rats and Fractionation of Their Hippocampi to Examine Seizure-induced Changes in Postsynaptic Density Proteins
Published on: August 15, 2017
07:54Testing Animal Anxiety in Rats: Effects of Open Arm Ledges and Closed Arm Wall Transparency in Elevated Plus Maze Test
Published on: June 29, 2018
Related Concept Videos
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Steady State Concentration
Most drugs are administered in repeated doses at fixed intervals or through continuous...
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...