Low-power versus medium-power toric intraocular lenses in cataract surgery, about 110 eyes
A Mairot1, H El Chehab1, E Agard1
1Desgenettes Military Hospital, 108, boulevard Pinel, 69003 Lyon, France.
Purpose:
To analyze the refractive predictability of low-power and medium-power toric intraocular lenses (IOL) during cataract surgery.
Methods:
A retrospective case series. Patients with low and moderate degrees of astigmatism were treated with either an Alcon AcrySof IQ toric monofocal lens (SN6AT2 or SN6AT3) or a Zeiss toric monofocal lens (709 MP + 1 D or 709 MP + 1.5 D). They were divided into two groups: group 1 with low-power toric IOL (n = 40, SN6AT2 and 709 MP + 1), group 2 with medium-power toric IOL (n = 70, SN6AT3 and 709 MP + 1.5 D). Eyes were evaluated before and 1 month after surgery. Uncorrected distance visual acuity (UDVA), corneal and total astigmatism were compared pre- and postoperatively. Vector astigmatism analysis was evaluated using the Alpins method. IOL alignment was checked postoperatively at slit lamp under pupil dilatation and on photos using Eyesuite® software (Luneau®).
Results:
More than three-quarters of the patients in each group attained a visual acuity of at least 0.1 LogMAR (0.8) without spectacles. The reduction of total astigmatism was significant in the two groups. The residual refractive astigmatism did not differ between the two groups (P = 0.64) and was less than 0.4 D. More than 80% of patients (82.5 vs 84.3%) presented a postoperative refractive spherical equivalent at ±0.50 D (P = 0.8). Vectorial astigmatism was significantly different in the two groups (0.43 D in group 1, vs 0.27 D in group 2; P = 0.03).
Conclusion:
This is the first study comparing the low- versus medium-power toric IOLs, the most widely used. This study suggests very good refractive results both with low- and medium-power toric IOLs with a single surgical procedure.
More Related Videos
05:19Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery
Published on: December 1, 2023
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
Related Concept Videos
Power
Sums of Power
Instantaneous Power
Complex Power
Complex power is defined as the multiplication of the voltage and the complex conjugate of the current. The magnitude of this power, known as apparent power, is measured in volt-amperes (VA). Notably, the angle of the complex power equates to the...
Electrical Power
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...