Abstract:
We compared the Lim/Tsai tendon repair technique using an extra-tendinous knot with modification using an intra-tendinous knot. The ultimate tensile strength, load to 2 mm gap force, stiffness, mode of failure, location of failure, and time taken to repair each tendon were recorded during a single cycle loading test in 20 tendons with each repair method. We found that the ultimate tensile strength and 2 mm gap force of the modified Lim/Tsai repair with an extra-tendinous knot (56 SD 5 N and 14 SD 2 N, respectively) were statistically significantly higher than that of the modified Lim/Tsai repair with intra-tendinous knot (51 SD 7 N and 11 SD 2 N, respectively). We conclude that the modified Lim/Tsai repair with extra-tendinous knot is stronger, despite having the same number of core strands.