Introduction:
The aim of this study was to evaluate the ability of pressurized water irrigation technique (AquaPick Device) as an intra-canal irrigation technique and compare it with sonic irrigation device (Endoactivator) for their ability to remove smear layer from canals.
Methods And Materials:
Total number of 80 single rooted teeth (premolars) were prepared, divided into eight main groups, Group 1: Aquapick with apically vented needle/18 mm depth, Group 2: Aquapick with apically vented needle/15 mm depth, Group 3: Endoactivator device/18 mm depth, Group 4: Endoactivator device/15 mm depth, Group5: Aquapick with 2 side vented needle/18 mm depth, Group 6: Aquapick with 2 side vented needle/15 mm depth and two control groups. Then all samples were tested by SEM in 3, 6 and 9-mm distances from the apical foramen. The data were statistically analyzed using Kruskal Wallis and Mann-Whitney U tests.
Results:
There was a high significant difference among the tested groups with the best removal of smear layer by the use of pressurized water irrigation device with apical vented needle especially at the 3 mm area.
Conclusion:
Pressurized water irrigation technique could be used as intra-canal irrigation technique with good results.
More Related Videos
Related Concept Videos
Design Example: Design of an Irrigation Channel
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Voltammetric Techniques: Linear-Scan (E vs Time)
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Leaky Scanning