Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles
Antonin Povolny1, Hiroshige Kikura2, Tomonori Ihara3
1Laboratory for Advanced Nuclear Energy, Tokyo Institute of Technology, Ookayama, Meguro-ku, Tokyo 152-8550, Japan. povolny@us.nr.titech.ac.jp.
Abstract:
Bubbly flows are commonly used in various applications and their measurement is an important research topic. The ultrasound pulse-echo technique allows for the detection of each bubble and the measurement of the position of its surface. However, so far it has been used only to measure single bubbles. This paper investigates whether the pulse-echo technique can be applied for measuring multiple bubbles concurrently. The ultrasonic transducer wavelength and diameter were selected based on expected bubble diameters so that each bubble produced a strong reflection. The pulse-echo was implemented to obtain good accuracy without sacrificing the signal processing speed. A tracking technique was developed for the purpose of connecting detected reflections to trajectories. The technique was tested experimentally by measuring the horizontal position of rising air bubbles in a water tank. The results show that the pulse-echo technique can detect multiple bubbles concurrently. The pulse-echo technique detected almost the same number of bubbles as a high-speed video. For average void fractions up to around 1 % (and instantaneous void fraction reaching 5.3 % ), the rate of bubbles missed by the pulse-echo and the rate of noise trajectories both stayed less than 5%. The error rate increased with the void fraction, limiting the technique’s application range.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Special considerations while measuring pulse
Voltammetric Techniques: Pulse Voltammetry
Excess Pressure Inside a Drop and a Bubble
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...