Optimization of the method of the content-containing interaction evaluation for cosmetic products by gas
C Charron1, S De Vaugelade1, F Richard1
1EXPERTOX Agency and Laboratory, 14 rue Godefroy Cavaignac, Paris, 75011, France.
Abstract:
In July 2013, the European Regulation (EC) No 1223/2009 came into effect in order to secure cosmetic products. The content-containing interaction between the packaging and the product must be considered for the safety assessment. Indeed, some compounds are able to migrate from the packaging to the product and may be harmful to the consumer health. This is why a first test was established by EXPERTOX laboratory in 2012 to deal with this new regulation. A new analytical method was developed and validated for the quantification of 23 substances able to migrate from the packaging to the product. It was applied on a plastic packaging with the five simulants of migration. To evaluate the content-containing interaction, a gas chromatography-mass spectrometry method was developed and validated. Liquid-liquid extraction was used to extract contaminants (thirteen phthalates and ten substances of very high concern) from migration simulants. Calibration curves showed good linearity regression from 2 to 50 μg mL-1 for nineteen molecules and from 5 to 45 μg mL-1 for the others. The limits of quantification were respectively 2 and 5 μg mL-1 . The accuracy, precision, repeatability of the analytical method and extraction yields were acceptable. No molecule was found in simulants of migration, so the potential contaminants present in the packaging did not migrate. A gas chromatography-mass spectrometry method and liquid-liquid extraction were validated for 23 molecules and can be used for the evaluation of the content-containing interaction of cosmetic products. Both quantification and extraction procedures are more robust and faster than previous method.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
