Performance evaluation of duplex constructed wetlands for the treatment of diesel contaminated wastewater
Related Experiment Video
Updated: Feb 11, 2026

Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment
Published on: May 2, 2025
Hassana Ibrahim Mustapha1, Pankaj Kumar Gupta2, Brijesh Kumar Yadav2
1UNESCO-IHE, P.O. Box 3015, 2601 DA, Delft, The Netherlands; Federal University of Technology, Minna, Department of Agricultural and Bio-resources Engineering, P. M. B. 65, Gidan Kwano. Nigeria.
Abstract:
A duplex constructed wetland (duplex-CW) is a hybrid system that combines a vertical flow (VF) CW as a first stage with a horizontal flow filter (HFF) as a second stage for a more efficient wastewater treatment as compared to traditional constructed wetlands. This study evaluated the potential of the hybrid CW system to treat influent wastewater containing diesel range organic compounds varying from C7 - C40 using a series of 12-week practical and numerical experiments under controlled conditions in a greenhouse (pH was kept at 7.0 ± 0.2, temperature between 20 and 23° C and light intensity between 85 and 100-μmol photons m-2 sec-1 for 16 h d-1). The VF CWs were planted with Phragmites australis and were spiked with different concentrations of NH4+-N (10, 30 and 60 mg/L) and PO43--P (3, 6 and 12 mg/L) to analyse their effects on the degradation of the supplied petroleum hydrocarbons. The removal rate of the diesel range organics considering the different NH4+-N and PO43--P concentrations were simulated using Monod degradation kinetics. The simulated results compared well with the observed database. The results showed that the model can effectively be used to predict biochemical transformation and degradation of diesel range organic compounds along with nutrient amendment in duplex constructed wetlands.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
05:40Comparison of Scale in a Photosynthetic Reactor System for Algal Remediation of Wastewater
Published on: March 6, 2017
Related Concept Videos
Otto and Diesel Cycle
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Bode Plots Construction
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Construction of Frequency Distribution
First, make a table with two columns—one with the title of the data that needs to be organized, and the other column for frequency. [Draw a third column for tally marks if needed]. Then, take a look at the items given in the data set and decide if an ungrouped frequency distribution table or a grouped frequency distribution table would be more suitable. If there are large sets of different values, then it is...
Pathophysiology of Cardiac Performance