Related Experiment Video
Updated: Feb 11, 2026

Generation and Culturing of Primary Human Keratinocytes from Adult Skin
Published on: December 22, 2017
Gender differences in the fluorescence of human skin in young healthy adults
M Morvová1, P Jeczko1, L Šikurová1
1Department of Nuclear Physics and Biophysics, Faculty of Mathematics, Physics and Informatics, Comenius University, Bratislava, Slovakia.
Background:
Human skin naturally contains many endogenous fluorophores; therefore, fluorescence techniques can be used for monitoring of the human skin even in in vivo mode. The aim of this work was to study skin autofluorescence in vivo regarding the possible effect of gender.
Materials And Methods:
Fluorescence emission spectra of young healthy Caucasian adults in 3 anatomical regions (forehead, hand, and inner upper arm) were taken with excitation at 280, 325, or 400 nm.
Results:
Three emission bands were found in the spectra for both men and women: (1) an intensive band peaked at 340/280 nm (peak emission/excitation wavelength), corresponding to aromatic amino acids of proteins in epidermis; (2) a broad band with emission between 360 nm and 480 nm (excitation 325 nm) with a base peak around 390 nm and 2 side peaks at 420 and 450 nm, mainly due to collagen cross-links in dermis with a possible weak contribution of elastin and mitochondrial NADPH; (3) a weak but distinct peak at 600/400 nm corresponding presumably to skin unmetalled porphyrins.
Conclusion:
The intensity of skin autofluorescence showed differences between genders and among anatomical regions. The 340 nm intensity was 1.4 times higher in the male group in all 3 anatomical regions studied. The highest intensity of skin autofluorescence for the peaks at 340/280 nm and 600/400 nm was found on the forehead, whereas the 390/325 nm band was most intensive on the inner upper arm in both genders.
Related Concept Videos
Socioemotional Experience and Gender Development
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
Difference Equation Solution using z-Transform
The z-transform facilitates handling delayed signals by shifting the signal in the z-domain, which corresponds to delaying the signal in the time domain, and advancing signals by similarly shifting in the...

