Infected Teflon felt strip-paracardiac abscess after Dor's procedure
R Karthik Raman1, Ejaz Ahmed Sheriff1, Rajan Sethuratnam1
1Department of Cardiac Surgery, Institute of Cardiovascular Diseases, Madras Medical Mission, Chennai, Tamil Nadu, India.
Abstract:
Foreign material used for reconstructing or suturing the cardiac chambers carries the risk of infection. When such a scenario is encountered, it is better to be aggressive in removing the infected source surgically, as conservative management will most often result in recurrence. Herein, we present an unusual case of infected prosthetic material after cardiac surgery that was managed surgically. This case reminds us of the surgical principle of eradicating the source of infection, which should be given priority.
Related Concept Videos
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Cardiac Catheterization II: Right Heart Catheterization
Endocarditis IV: Nursing Management