Related Experiment Video
Updated: Feb 11, 2026

Transarterial Administration of Oncolytic Viruses for Locoregional Therapy of Orthotopic HCC in Rats
Published on: April 15, 2016
Fully validated SRM-MS-based method for absolute quantification of PIVKA-II in human serum: Clinical applications for
Areum Sohn1, Hyunsoo Kim2, Injoon Yeo3
1Department of Biomedical Sciences, Yongon-Dong, Seoul, 110-799, Republic of Korea; Department of biomedical Engineering, Yongon-Dong, Seoul, 110-799, Republic of Korea.
Abstract:
Protein induced by vitamin K absence or antagonist-II (PIVKA-II), an abnormal form of prothrombin, is used as a serological biomarker that aids in the diagnosis of hepatocellular carcinoma (HCC). PIVKA-II is typically measured by liquid binding assay (LiBA). However, without an internal standard, it is difficult to obtain accurate results. Thus, we aimed to develop a selected reaction monitoring-mass spectrometry (SRM-MS)-based assay to quantify PIVKA-II in serum. Our SRM-MS assay entailed the addition of a protein analog as an internal standard, the enrichment of PIVKA-II using a monoclonal antibody, chymotrypsin digestion, online desalting, and SRM-MS analysis. The performance of the SRM-MS assay was compared with that of LiBA in 400 human serum samples (100 chronic hepatitis, 100 liver cirrhosis, and 200 HCC). Integrated multinational guidelines were followed to validate the assay for clinical implementation. The linearity ranged from 1.28 to 100,000 ng/mL, and the use of a labeled protein analog as an internal standard allowed the error from the sample preparation to be corrected, improving the precision and accuracy. The SRM-MS assay was validated to meet all of the criteria of the compliance with guidelines per the US Food and Drug Administration (FDA), European medicines agency (EMA), Korea FDA (KFDA), and Clinical & Laboratory Standards Institute (CLSI). We have developed and validated a robust and reproducible SRM-MS assay that is superior to the conventional method of distinguishing HCC from noncancer patients, based on PIVKA-II levels, and satisfies clinical standards. This method has potential applications in quantifying other protein biomarkers.
Related Concept Videos
Clinical Applications of Epidermal Stem Cells
Absolute Value Inequalities
Mean Absolute Deviation
Let us consider a dataset containing the number of unsold cupcakes in five shops: 10, 15, 8, 7, and 10. Initially, calculate the sample mean. Then calculate the deviation, or the difference, between each data value and the mean. Next, the absolute values of these deviations are added and divided by the sample size to...
Reliability and Validity
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...

