Related Experiment Video
Updated: Feb 11, 2026

A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery
Published on: May 20, 2016
Integration of radiobiological modeling and indices in comparative plan evaluation: A study comparing VMAT and 3D-CRT
Soumyajit Roy1, Iulian Badragan2, Sheikh Nisar Ahmed1
1Department of Radiation Oncology, British Columbia Cancer Agency-Abbotsford Center, Canada; Division of Radiation Oncology and Developmental Radiotherapeutics, University of British Columbia, Canada.
Purpose:
The purpose of this article was to generate an algorithm to calculate radiobiological endpoints and composite indices and use them to compare volumetric modulated arc therapy (VMAT) and 3-dimensional conformal radiation therapy (3D-CRT) techniques in patients with locally advanced non-small cell lung cancer.
Methods And Materials:
The study included 25 patients with locally advanced non-small cell lung cancer treated with 3D-CRT at our center between January 1, 2010, and December 31, 2014. The planner generated VMAT plans using clones of the original computed tomography scans and regions of interest volumes, which did not include the original 3D plans. Both 3D-CRT and VMAT plans were generated using the same dose-volume constraint worksheet. The dose-volume histogram parameters for planning target volume and relevant organs at risk (OAR) were reviewed. The calculation engine was written in the R programming language; the user interface was developed with the "shiny" R Web library. Dose-volume histogram data were imported into the calculation engine and tumor control probability (TCP), normal tissue complication probability (NTCP), composite cardiopulmonary toxicity index (CPTI), morbidity index: MI = ∑j = 1#ofrelevantOARs(wj ∗ NTCPj), uncomplicated TCP (UTCP=TCP∗∏k=1#ofOARs1-NTCPK100, and therapeutic gain (TG): ie, TG = TCP ∗ (100 - MI) were calculated.
Results:
TCP was better with 3D-CRT (12.62% vs 11.71%, P < .001), whereas VMAT demonstrated superior NTCP esophagus (4.45% vs 7.39%, P = .02). NTCP spinal cord (0.001% vs 0.009%, P = .001), and NTCP heart/perfusion defect (44.57% vs 56.42%, P = .016). There was no difference in NTCP lung (6.27% vs 7.62%, P = .221) and NTCP heart/pericarditis (0.001% vs 0.15%, P = .129) between 2 techniques. VMAT showed substantial improvement in morbidity index (11.06% vs. 14.31%, P = 0.01), CPTI (47.59% vs 59.41%, P = .03), TG (P = .035), and trend toward superiority in UTCP (5.89 vs 4.75, P=.057).
Conclusion:
The study highlights the utility of the radiobiological algorithm and summary indices in comparative plan evaluation and demonstrates benefits of VMAT over 3D-CRT.
Related Concept Videos
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Comparative Excretory Systems
Comparing Experimental Results: Student's t-Test
Comparing the Survival Analysis of Two or More Groups
Comparing Mitochondrial, Chloroplast, and Prokaryotic Genomes
Comparing Intermolecular Forces: Melting Point, Boiling Point, and Miscibility
Temporary attractive forces like dispersion are present in all molecules, whether they are polar or nonpolar. They...